ATEN 16A 16-voudige Switched Bank Metered PDU + gratis Eco PDU Manager Software

ATEN 16A 16-voudige Switched Bank Metered PDU + gratis Eco PDU Manager Software
ATEN 16A 16-voudige Switched Bank Metered PDU + gratis Eco PDU Manager Software
611,95 €
The ATEN PE6216 is a 0U monitored power distribution unit (PDU) from the NRGence line, featuring 16 AC outlets with C13 and C19 couplers and a 3 m power cable. Designed for rack environments, this intelligent eco PDU provides remote, centralised control and real-time power measurement to improve dat... Lees meer
Voorraad Niet op voorraadGeen voorraad Code 1728024 Merk ATEN Model PE6216G-AX-G Garantie 2 jaar

Bezorging & retourneren

The ATEN PE6216 is a 0U monitored power distribution unit (PDU) from the NRGence line, featuring 16 AC outlets with C13 and C19 couplers and a 3 m power cable. Designed for rack environments, this intelligent eco PDU provides remote, centralised control and real-time power measurement to improve data centre power efficiency. It supports SNMP v1/v2/v3 and works with ATEN eco Sensors and eco PDU Manager software for environmental monitoring and device management.

Advantages

The PE6216 offers individual outlet-level on/off and power cycling, combined with real-time measurement of current, voltage, power and energy (watt-hour). Its networked TCP/IP access enables remote management of attached devices and comprehensive power analysis reports. Compatibility with standard SNMP managers and ATEN's eco software provides flexible monitoring and centralized configuration, while built-in security features help protect access to power controls.

Suitable for

  • Rack-mounted servers and storage systems
  • Network devices and KVM switches
  • Small to medium data centre racks requiring monitored PDUs
  • Environments needing outlet-level power control and energy monitoring

Key specifications

  • Product: Power Distribution Unit ATEN PE6216 (PE6216G-AX-G)
  • PDU type: Monitored, 0U
  • AC outlets: 16 (C13/C19 couplers)
  • Nominal input voltage: 100–240 V
  • Maximum current: 20 A
  • Frequency: 50–60 Hz
  • Cable length: 3 m
  • Weight: 3.7 kg
  • Colour: Black
  • Management: SNMP v1/v2/v3, TCP/IP; compatible with ATEN eco Sensors and eco PDU Manager

How to use

Install the PE6216 in a rack as a 0U PDU and connect the unit to the mains using the integrated 3 m cable. Attach IT equipment to the appropriate C13 or C19 outlets. Configure network settings (IP address, SNMP credentials) via the device web interface or ATEN eco PDU Manager. Use the interface or SNMP management tool to view real-time power metrics and to perform outlet-level on/off or power-cycle operations.

Recommendations

Connect power-hungry devices to appropriate outlets (C19 for higher current draw) and use the per-outlet monitoring to balance loads across the rack. Regularly update access credentials and management software, and integrate environmental sensors for temperature and humidity monitoring to ensure reliable operation and accurate energy reporting.

Belangrijkste kenmerken
  • Space saving 0U rack mount design with rear mounting
  • IEC or NEMA outlet models
  • 3 x 7-segment front panel LED shows Current / IP Address for PDU / Bank
  • Remote users can monitor PDU/Bank status via web pages on their browsers
  • Safe shutdown support
  • Separate power for the unit´s own power and its power outlets – the user interface is still accessible even when an overload condition trips the devices´ circuit breaker
  • Remote power control via TCP/IP and a built in 10/100 Ethernet port
  • Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, auto sense, Ping, Telnet
  • eco PDU Power Management software – eco Sensors
  • Supports SNMP Manager V1, V2 & V3
  • Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
  • Easy setup and operation via a browser-based user interface
  • Multibrowser support (IE, Mozilla, Firefox, Chrome, Safari, Opera, Netscape)
  • RTC support to keep the timer running during times of no power
  • Up to 8 user accounts and 1 administrator account
  • Proactive Overload Protection (POP) – automatically powers off outlets when current overloads to protect operating devices
  • Power status measurement at the PDU/Bank level
  • LED indicators for current and IP address at the PDU device and/or Bank levels
  • Real-time aggregate current, voltage, and power and power dissipation displayed in a browser-based UI for monitoring at the PDU level
  • Environment monitoring – supports external temperature / humidity / Differential Pressure sensors for rack environment monitoring
  • Current and voltage threshold setting
  • Naming support for outlets
  • User outlet access assignment on an outlet-by-outlet basis
  • Event logging and syslog support
  • Upgradeable firmware
  • Multilanguage support: English, Traditional Chinese, Simplified Chinese, Japanese, German, Italian, Spanish, French, Russian
Specificaties
Aantal AC-uitgangen
16 AC outlet(s)
AC-ingangsfrequentie
50-60 Hz
Bedrijfstemperatuur (T-T)
0 - 40 °C
Belastbaarheid
3680 VA
Beveiligingsalgoritmen
SNMP, SNMPv2, SNMPv3
Breedte
1324.8 mm
Breedte omdoos
187 mm
Breedte verpakking
187 mm
Brutogewicht omdoos
6.02 kg
Certificering
CE, C-Tick TUV-CB, GOST
Diepte
66 mm
Diepte verpakking
1415 mm
Ethernet LAN (RJ-45)-poorten
1
Gewicht
4.27 kg
Gewicht verpakking
6 kg
Handleiding
Yes
Hoogte
44 mm
Hoogte omdoos
179 mm
Hoogte verpakking
179 mm
Kabellengte
3 m
Kabels inbegrepen
AC
Led-indicatoren
Yes
Lengte omdoos
1415 mm
Maximale stroomsterkte
16 A
Monitoring
Current, Voltage
Nettogewicht omdoos
4.27 kg
Nominale ingangsspanning
100-240 V
Ondersteunde netwerkprotocollen
TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, Ping, Telnet
Opslagtemperatuur (T-T)
-20 - 60 °C
PDU-typen
Metered, Switched
Producten per omdoos
1 pc(s)
Productkleur
Black
Rackcapaciteit
0U
Rackmontageset
Yes
Relatieve luchtvochtigheid bij opslag (H-H)
0 - 80%
Relatieve luchtvochtigheid tijdens gebruik (H-H)
0 - 80%
Stroombeveiligingsfuncties
Overload
Stroomstekker
C20 coupler
Type stopcontacten
C13 coupler, C19 coupler
Prijsverloop van de afgelopen 6 maanden
ATEN 16A 16-voudige Switched Bank Metered PDU + gratis Eco PDU Manager Software
Actueel
611,95 €
Laagste
611,95 €
Hoogste
644,36 €
Wijziging 24 uur
-2,73 €   0%
Week
-2,29 €   0%
Maand
—   

Review schrijven

Beoordeling *
Je naam wordt openbaar getoond – je mag ook een bijnaam gebruiken. We nodigen kopers uit om reviews te schrijven. We controleren reviews vóór plaatsing en plaatsen ook kritische reviews.

Populaire producten in deze categorie

Verkoper: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litouwen · Bedrijfsnummer 303192950 · Btw-nummer LT100008198612 · Verzending vanuit de EU (Litouwen)
Hoi, ik ben de AI-assistent van DistriNode. Ik help je graag met het vinden van producten, het vergelijken van opties, het maken van offerte-PDF's of het openen van supportaanvragen.
Alle categorieën