Brandmeldkabel BITNER YnTKSYekw 2x2x0,8, 100 m lengte

Brandmeldkabel BITNER YnTKSYekw 2x2x0,8, 100 m lengte
Brandmeldkabel BITNER YnTKSYekw 2x2x0,8, 100 m lengte
74,10 €
BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control... Lees meer
Voorraad 6 Code 1715354 Merk BITNER Model 41369K Garantie 2 jaar

Bezorging & retourneren

Verwachte bezorgdatum donderdag, oktober 15
Je blijft op de hoogte via ons uitgebreide trackingsysteem
Betaalopties
BetaalkaartVisaMastercardPayPalApple PayGoogle PayBankoverschrijving

BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control panels, sounders and other low-voltage fire safety devices. The construction is intended for fixed installations in buildings and technical facilities where reliable signal transmission and clear pairing are required.

Advantages

The cable offers stable electrical characteristics for short- and medium-distance signalling runs and maintains signal integrity through paired conductors that reduce interference. A 100 m reel simplifies handling and installation planning for typical fire protection circuits. The product is suitable for fixed wiring with straightforward routing and termination using standard tools and connectors compatible with fire alarm equipment.

Suitable for

Key specifications

How to use

Plan the routing route from detectors to the control panel and measure required lengths allowing extra for terminations. Strip the outer sheath and separate conductors carefully to avoid nicking the copper. Use appropriate fire-alarm compatible connectors or terminal blocks to terminate each pair, maintaining pair integrity to preserve signal quality. Secure the cable along cable trays, conduits or mounting points according to building regulations and fire safety standards, avoiding sharp bends and mechanical stress. Test continuity and signal transmission after installation and before commissioning the fire alarm system.

Recommendations

Install the cable in accordance with local electrical and fire safety codes. Keep separation from high-voltage power lines to reduce electromagnetic interference and route in protected pathways where possible. Use junction boxes or approved connectors for splices, and verify compatibility with the fire alarm control panel and peripheral devices prior to final connection.

Belangrijkste kenmerken
  • Wiring between fire detectors and fire control panels
  • Connections to sounders, sirens and notification devices in alarm systems
  • Short- to medium-length signalling runs inside commercial and residential buildings
  • Fixed low-voltage installations in technical rooms and service shafts
  • Conductor configuration: two twisted pairs (2x2)
  • Conductor diameter: 0.8 mm
  • Cable type: signalling/control for fire alarm systems
  • Length: 100 m reel
  • Application: fixed indoor installation for low-voltage signalling
Prijsverloop van de afgelopen 6 maanden
Brandmeldkabel BITNER YnTKSYekw 2x2x0,8, 100 m lengte
Actueel
74,10 €
Laagste
68,56 €
Hoogste
83,54 €
Wijziging 24 uur
+1,11 €   +2%
Week
+0,80 €   +1%
Maand
+5,53 €   +8%
Hoi, ik ben de AI-assistent van DistriNode. Ik help je graag met het vinden van producten, het vergelijken van opties, het maken van offerte-PDF's of het openen van supportaanvragen.