Conteg ventilatiemodule met 4 ventilatoren geregeld

Conteg ventilatiemodule met 4 ventilatoren geregeld
Conteg ventilatiemodule met 4 ventilatoren geregeld
296,87 €
Data center operators and IT managers often face the challenge of maintaining optimal temperatures in densely packed server racks. The CONTEG DP-VEN-04-H is a 1U rack mount fan unit engineered to deliver active cooling where passive airflow falls short. With four thermostat-controlled axial fans, it... Lees meer
Voorraad 2 Code 3397306 Merk CONTEG Model DP-VEN-04-H Garantie 2 jaar

Bezorging & retourneren

Verwachte bezorgdatum woensdag, oktober 21
Je blijft op de hoogte via ons uitgebreide trackingsysteem
Betaalopties
BetaalkaartVisaMastercardPayPalApple PayGoogle PayBankoverschrijving

Data center operators and IT managers often face the challenge of maintaining optimal temperatures in densely packed server racks. The CONTEG DP-VEN-04-H is a 1U rack mount fan unit engineered to deliver active cooling where passive airflow falls short. With four thermostat-controlled axial fans, it automatically adjusts speed based on real-time temperature readings, ensuring your equipment stays within safe operating limits without manual intervention.

Key specifications

  • Mounting: 19-inch rack mount, 1U height
  • Number of fans: 4 axial fans
  • Control: Thermostat-controlled with integrated temperature sensor
  • Maximum airflow: 480 m³/h
  • Maximum noise level: 50 dB(A)
  • Power supply: 230V AC, 50/60 Hz, 45 W consumption
  • Power connector: IEC C14 inlet
  • Material: Steel, black (RAL 9005)
  • Operating temperature: 0°C to +50°C
  • Protection class: IP20
  • Certifications: CE, RoHS

Why choose it

This fan unit is built to handle the thermal demands of modern server and network cabinets. The automatic speed regulation based on internal temperature not only optimizes cooling performance but also reduces energy consumption and noise during low-load periods. Its robust steel construction and standard 1U form factor make it a durable and space-efficient addition to any rack.

Ideal use cases

  • Cooling high-density server racks in data centers
  • Enhancing airflow in network cabinets with active equipment
  • Supplementing cooling in IT closets or edge computing environments
  • Preventing hot spots in racks with limited ventilation

Good to know

The unit connects via a standard IEC C14 inlet, allowing easy integration with common rack power distribution units. Installation is straightforward in any 19-inch rack, and the black finish matches most rack aesthetics. Regular maintenance is minimal—just ensure the fans remain free of dust for optimal performance.

Specificaties
Aan-/uitschakelaar
Yes
AC-ingangsfrequentie
50/60 Hz
Bedrijfstemperatuur (T-T)
0 - 50 °C
Breedte
482 mm
Categorie
Rack Fan Unit
Conformiteitscertificaten
CE, RoHS
Daisy chain
No
Diepte
250 mm
Gewicht
3.5 kg
Hoogte
44 mm
Kabellengte
No
Led-indicatoren
Power, Fan status
Maximale stroomsterkte
10 A
Merk
CONTEG
Model
DP-VEN-04-H
MPN
DP-VEN-04-H
Overspanningsbeveiliging
No
Productkleur
Black
Rackcapaciteit
1U
Stroomstekker
IEC C14
Type
Fan Unit
Vormfactor
1U Rackmount
Wachtwoordbeveiliging
No
Prijsverloop van de afgelopen 6 maanden
Conteg ventilatiemodule met 4 ventilatoren geregeld
Actueel
296,87 €
Laagste
295,78 €
Hoogste
299,40 €
Wijziging 24 uur
+0,67 €   +0%
Week
+0,21 €   +0%
Maand
+0,63 €   +0%